SECTION 6 - JLG CONTROL SYSTEM

3121180

– JLG Lift –

6-55

DATALOG:

ON

XXXXhXXm

Total controller on (EMS) time

ENGINE

XXXXhXXm

Engine run time

DRIVE

XXXXhXXm

Total controller drive operation time

LIFT

XXXXhXXm

Total controller lift operation time

SWING

XXXXhXXm

Total controller swing operation time

TELE

XXXXhXXm

Total controller telescope operation time

MAX TEMP

XXC

Maximum measured ambient temp.

MIN TEMP

XXC

Minimum measured ambient temp.

MAX volts

XX.XV

Maximum measured battery voltage

RENTAL

XXXXhXXm

Total controller operation time. NOTE: can be reset

ERASE RENTAL?

Not available at Access Level 2.
ENTER resets rental data log time to zero.

VERSIONS:

GM SW

PX.X

Ground module software version

GM HW REV

XXXX

Ground module hardware revision

GM SN

XXXXXX

Ground module serial number

PM SW

PX.X

Platform module software version

PM HW REV

XXXX

Platform module hardware revision

PM SN

XXXXXX

Platform module serial number

cm sw

PX.X

Chassis module software version

bm sw

PX.X

BLAM module software version

c pin SW

Cylinder moment load pin transmits software version.

C PIN SN

Cylinder moment load pin transmits serial number.

ANALYZER

VX.XXXX

Analyzer software version

Table 6-6. Machine Diagnostics Parameters

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter (Displayed

on Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description