JLG 450A_AJ Series II Service Manual User Manual

Page 395

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121180

– JLG Lift –

6-59

Table 6-8. Help Fault Codes, Displayed Faults, and Descriptions - S/N 0300066949 & S/N 1300000001 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority

None

No flash code is indicated for the following help messages. They are intended
to hint at a possible problem if vehicle is not behaving as expected.

1

EVERYTHING OK

The “normal” help message in platform mode

GROUND MODE OK

The “normal” help message in ground mode

FSW OPEN

A drive or boom function has been selected but footswitch is open.

RUNNING AT CREEP – CREEP
SWITCH OPEN

All function speeds are limited to creep because the creep switch is open.

RUNNING AT CREEP – TILTED AND
ABOVE ELEVATION

All boom function speeds are limited to creep because vehicle is tilted and
above elevation.

RUNNING AT CUTBACK – OUT OF
TRANSPORT POSITION

Drive speed is limited to “ELEVATED MAX” because vehicle is out of transport
position.

CHASSIS TILT SENSOR OUT OF
RANGE

The chassis tilt sensor has indicated a tilt angle greater than 19 degrees for
more than 4 seconds. Not reported during 2 second power-up.

LOAD SENSOR READING UNDER
WEIGHT

Load sensor is reading 20% or more under calibrated zero point. This fault may
occur if basket is resting on ground. Not reported during 2 second power-up.

ENVELOPE ENCROACHED –
HYDRAULICS SUSPENDED

Machines with envelope control ONLY. System has detected an envelope
violation

OVER MOMENT – HYDRAULICS SUS-
PENDED

Only occurs on machines with moment control. The system has detected an
over moment violation.

UNDER MOMENT – HYDRAULICS
SUSPENDED

Machines with moment control ONLY. System has detected an under moment
violation.

1/1

Flash code 1/1 indicates a “sleep” mode.
NOT REQUIRED

2/1

Flash code 2/1 indicates problems with footswitch.

2

FSW FAULTY

The two footswitch inputs have read the same state for more than one second.
An EMS cycle is required.

KEYSWITCH FAULTY

Platform and ground modes selected simultaneously

Advertising