Setting the properties tab 9.1 – 2N PBX 2N NetStar - Configuration Manual v2.6.0 User Manual

Page 114

Advertising
background image

Setting the properties tab

9.1

114

can find on all levels.

a) Basic

Parameters of this tab are mostly divided into sections according to their function:
No answer timeout [ms] – This parameter sets maximum time of alerting of the called phone.

After expiration of this timeout is call establishment terminated with cause "user not responding" and

calling user hears congestion tone. Default value of this parameter is 180s.
Next call – With this parameter you can set up caution about incoming queued call. Default value of

this parameter is "NO" (caution is disabled). This function isn't implemented in the current version of

firmware.

Holdoff parameters
Hold
– With this option you can enable holding of the call (Hold). Default value of this parameter is

"YES" (hold is enabled).
Hold tone – With this option you can set up the tone which will be played to the user in the case of

holding of his call by opponent. Default tone is progress tone Music on Hold.

Transfer parameters
ECT enabled
– (Explicit Call Transfer) – With this parameter you can enable call transfer via external

interface (e.g. CTI phone).
ICT enabled – (Implicit Call Transfer) – With this parameter you can enable call transfer via

connected terminal (phone). You can use one of the following transfers:
Blind transfer – Before transfer isn't call accepted by the user. E.g. user A calls to the user B. User

B accepts the call and A and B are talking. User B holds the call. User A hears Music on Hold and

user B establishes new connection to user C. User C doesn't accept the call and user B terminates the

call. User A is transferred to the user C and instead of Music on Hold he hears alert tone and when

user C accepts the call, they can talk to each other.
Transfer without hang out – Before transfer is call accepted by the user. E.g. user A calls to the

user B. User B accepts the call and A and B are talking. User B holds the call. User A hears Music on

Hold and user B establishes new connection to user C. User C accepts the call and then user B

terminates the call. User A is connected to the user C and they can talk to each other.
Transfer return timeout [ms] – This parameter defines timeout for return from transfer. It is used

in the case of blind transfer. After expiration of this timeout (if call isn't accepted) returns call to the

station which has transferred the call. Default value of this parameter is 20s.

Queue parameters
Queue
– With this option you can enable call queuing. It means, that if incoming call is routed to the

busy station with enabled queue, call isn't terminated and calling user hears alert tone and he can

wait for connection. After terminating of active call, the phone of called user will be alerted again with

your call from the queue. Without enabled queue is incoming call on busy station terminated with

cause "user busy". Default value of this parameter is "NO" (queue is disabled).
Queue depth – With this parameter you can set maximum of queued calls. All other incoming calls

will be rejected in the same way as the queue isn't enabled (cause user busy). If you set this

parameter to "zero", it means unlimited count of queued calls. Default value of this parameter is

"zero" (unlimited).
Queue timeout [ms] – This parameter defines delay between end of previous call and beginning of

new alerting with call from the queue. Default value of this delay is 0s (call begins alert without

Advertising