BRI and PRI virtual ports

3.1

25

Settings for SLIP – With parameter Nonsynchronous as error you can enable another

parameters for setting SLIP range. This option can be used only on TE port. If SLIP rate gets over

upper level, is this fact signalized by red exclamation on the port within menu

Hardware – Boards

and by red text in the field for stact status. For changing status of nonsynchronous line must SLIP

rate go under lower level. Interval between these two values is used as hysteresis.
Settings for BER – With parameter BER as error you can enable another parameters for setting

BER range. If BER rate gets over upper level, is this fact signalized by red exclamation on the port

within menu

Hardware – Boards

and by red text in the field for stact status. For changing status of

line with higher bit error rate must BER rate go under lower level. Interval between these two

values is used as hysteresis. BEr values are entered in exponential form (e.g. 3e-5 means 3 errors in

100000 bits).

Figure 2 View of jumper configuration for ISDN PRI board. Thick line presents front side of the

board.

Specific interface parameters
Prefer CRC
– With this option you can enable prefered communication with Cyclic Redundancy

Check. In this mode PbX at first try to establish connection with CRC and if it fails then it tries to

establish connection without CRC.
Long haul – With this parameter you can activate extended bus. If you use only one terminal and if

you hold impedance, you will be able to reach distance about 1000 metres between your equipments.

This parameter can be set only on port in NT mode.

DSS1 protocol parameters
Revers mode NT/TE
– This option refers only to L3 signaling. After checking this option will TE port

behave as NT port (and NT as TE).
Don't send time at NT – With this option you can disable sending of information element Date and

time within the message Connect from NT port to terminal (or TE port). It could be set only on NT

port.
Ignore unset explicit channel – With this option you can enable call establishment without

explicitly set B-channel.
Always select B-channel – With this option you can disable sending information element Channel

identification within the message Setup with signaling of any channel. It means that TE port have to

specify concrete B-channel. It could be set only on TE port.
Disconnect L2 – Parameter is used for L2 disconnection on interface without calls. Layer is

automatically disconnected by PbX after timeout expiration. Incoming call automatically connects

this layer.
Keep L2 connected – When this option is checked, PbX always try to keep L2 connected on this

interface and you don't need to connect interface by additional calls. This option can't be combined

with option Disconnect L2.
Disconnected L2 as error – With this option you can activate caution about disconnected second