190

Detector Setup

Detector status  -  this  parameter  displays  the  current  status  of  the  detector
(Active, Inactive, Unknown). With the 

 option, the assigned binary port

Unknown

is probably configured as an output or the port or board is unavailable
Tone connected  -  sets  the  tone  to  be  played  to  the  calling  user  when  the
detector gets in the active state upon pick up. The playing mode depends on the 

 and 

 parameters.

Timeout

Play whole tone

Tone disconnected  -  sets  the  tone  to  be  played  to  the  calling  user  whenever
the detector gets in the inactive state upon pick up. The playing mode depends
on the 

 and 

 parameters.

Timeout

Play whole tone

Tone events enabled - sets the tone to be played to the calling user when the 

 is checked. The playing mode depends on the 

 and 

Send events

Timeout

Play

 parameters.

whole tone
Timeout
  -  use  this  parameter  to  set  the  call  duration.  After  the  time  limit,  the
call is hung up (unless the following option is checked).
Play whole tone  -  use  this  option  to  enable  playing  the  whole  tone
independently of the preset time limit.
Send events - use this option to enable SMS sending for predefined events.
Send as user - use this parameter to define a user as an SMS sender. Be sure
to select the SMS routing parameters for the SMS sender.
Destination for events - use this section to define the destination for sending
the  detector  status  messages.  Select  a  user,  extension  or  number.  SMS
messages  to  users  and  extensions  are  routed  directly  but  those  routed  to  an
address use the From port of user routing as set in the Send as user parameter.

Advertising