Dss1 protocol parameters, Digital interface diagnostic – 2N NetStar Admin manual User Manual

Page 41

Advertising
background image

41

DSS1 protocol parameters

Reverse mode NT/TE  –  this  option  refers  to  L3  signalling  only.  Check  this
option to make a TE port behave as an NT port (and vice versa).
Do not send time at NT – use this option to disable sending of the connection
date and time information within the CONNECT message from an NT port to a TE
port. Available for NT ports only.
Ignore unset explicit channel  –  use  this  option  to  enable  call  establishment
without an explicitly set B–channel.
Always select B–channel  –  use  this  option  to  disable  sending  the  Channel
identification  information  within  the  SETUP  message  with  channel  signalling.
Available for TE ports only.
Disconnect L2 if no call  –  use  to  disconnect  the  L2  layer  on  an  inactive
interface.  The  PBX  automatically  disconnects  the  layer  after  a 

.  An

timeout

incoming call automatically reconnects the layer.
Keep L2 connected  –  check  this  option  to  make  the  PBX  keep  the  L2  layer
connected  on  this  interface  without  any  incoming  call.  This  option  may  not  be
combined with the 

 option.

Disconnect L2 if no call

Disconnected L2 as error  –  use  this  option  to  activate  a  caution  about  the
second layer being disconnected. This fact is indicated by a red exclamation mark
on the port in the 

 menu and a red text in the upper stack

Hardware – Boards

status field. This option may not be combined with the Disconnect L2 if no call
option.
Terminals – not applied for PRI ports.

 

 is able to process (i.e. resend to an interface other than

2N NetStar

®

ISDN) only G.711 A-law encoded calls on the ISDN interface. Calls
encoded by G.711 µ-law can only be resent between the ISDN
interfaces in the PBX.

Digital interface diagnostic

Line state  –  the  parameter  cannot  be  set.  It  only  shows  the  state  of  the  first
interface layer.
Number of SLIPs per minute – this parameter gives the count of slips. A slip is
caused  by  different  clocks  of  the  PBX  and  the  active  terminal.  This  value  is
updated every 6 seconds and represents a weighted average per minute.
Bit error rate per second  –  the  BER  parameter  gives  a  count  of  incorrectly
transferred  bits  during  transmission.  The  value  is  updated  every  6  seconds  and
represents a weighted average per minute.

If the 

 port supervision is used, enable some or all of the following parameters: 

SNMP

Inactive L1 as error Disconnected L2 as error Nonsynchronous L1 as error

. If not, the port error will not be detected and the PBX will be unable to

BER as error
send a warning.