Inbound way parameters (to PBX)

Ring pulse time [ms]  –  this  parameter  sets  the  minimum  time  of  the  ring
signal  presence  needed  for  ring  detection.  If  the  ring  time  is  shorter  than  the
preset value, ringing will be ignored.
Ring pulse treshold [V] – this parameter sets the minimum ring voltage level
needed for ring detection. If the ring voltage level is lower than the preset value,
ringing will be ignored.
Ring pattern time [ms] – this parameter sets the minimum period of time for
alerting detection.
CLI reception mode  –  the  parameter  defines  the  preferred  CLIP  (Calling  Line
Identification Presentation) reception type. Choose 

 or 

.

DTMF FSK

none

CLI reception timeout [ms] – the parameter sets the CLI detection timeout as
counted from the end of the first ring. This option is active only if the 

 or 

DTMF

 reception mode has been selected.

FSK
Polarity timeout [ms]
 – the parameter sets the reverse polarity timeout. This
option  is  active  only  if  the 

  item  has  been  selected  for  this

Reverse polarity

virtual port.
Call reject timeout [ms]  –  if  the  PBX  needs  to  reject  an  incoming  CO  call,  it
has  to  pick  up  and  hang  up.  Use  this  parameter  to  define  the  timeout  for  this
action. If the action is too short, the other party will not recognise termination.

Expert

Chipset

Chipset Type  –  this  parameters  determines  the  type  of  the  chipset  used.  The
SILABS_SI350 chipset is only supported at present.
Chipset Config – activates one of the chipset configurations created.
New config – helps create a new configuration for the selected chipset type.

Specific Chipset Config

Name – sets the chipset type whose configuration is being set in the section.

Do not change the above mentioned parameters unless absolutely
necessary.

DCTerm  –  sets  the  DC  termination  parameters  (ringing  voltage,  minimum
current, impedance). Hexadecimal values are used.
DAA Ctrl 5  –  sets  further  parameters  for  analogue  line  matching  (on/off-hook
rate, low pass filter). Hexadecimal values are used.
ACIM – helps set the proper impedance. Hexadecimal values are used.
Tx Gain – sets the transmit gain.
Rx Gain – sets the receive gain.

Refer to pages 78 to 81 of the User Manual for more details on the
parameters.

The table below includes the ACIM settings including meanings.