Product description
Power supply modules
I/O supply and electronic supply − EPM−S702
l
233
EDSIO1000 EN 7.0
Terminals
Module terminals, spring terminals
2
View
Designation
Explanation
Terminal data
2
6
3
7
4
8
1
5
1
5
4
8
1
Not assigned
10 mm
0.08 ... 1.5 mm²
(AWG 28 ... 16)
2
I/O supply +24 V DC
3
I/O supply 0 V
4
Electronic supply +24 V DC
5
Not assigned
6
I/O supply +24 V DC
7
I/O supply 0 V
SLIO002
8
Electronic supply 0 V
)
Note!
ƒ
Terminals 2 and 6 as well as 3 and 7 are bridged internally. Please note that
the max. permissible bridge current is 5 A.
ƒ
Both the I/O supply and the electronic supply are protected against overload
internally by a fuse. When the fuses have been tripped, the main supply of
the bus coupler (EPM−S700) must be replaced (
¶ 726).