2 protocol data, 3 communication time, Protocol data – Lenze E84DGFCT User Manual

Page 18: Communication time, Communication manual 8400 motec ethercat

Advertising
background image

Communication manual 8400 motec EtherCAT®

Technical data

Protocol data

18

L

EDS84DMOTECAT EN 2.1 - 11/2012

4.2

Protocol data

4.3

Communication time

Parameter data (SDO)
The communication time for parameter data is the time between the transmission of an

SDO request and the arrival of a corresponding response.

 The processing time in the controller is approx. 10 ms + a tolerance of +20 ms (typically)
 Some codes may require a longer processing time (see software manual / »Engineer«

online help "Inverter Drive 8400 motec").

Process data (PDO)
The communication time for process data is the time between the reception of a PDO with

setpoints and the return of a PDO with current actual values.
The communication times for process data depend on the ...

 processing time in the controller (interval time of the application task, process data

mode)

 runtime on the bus (telegram length, number of nodes, PDO update time, instant of

transmission of the EtherCAT frame)

The processing time starts when the setpoints are taken over by the controller at a point in

time which is not synchronised with the EtherCAT master, and ends when the current

actual values are provided at the EtherCAT interface.
Hence, the following holds true for the processing time:
1.3 ms + 1.0 ms (tolerance) + interval time of the application task

Area

Values

Process data words

1 ... 10 process data words to master (max. 20 bytes, 16 bits / word)

1 ... 8 process data words from master (max. 16 bytes, 16 bits / word)

Parameter data (mailbox size for CoE

transfer)

Max. 128 bytes