3 external voltage supply, External voltage supply – Lenze E84DGFCT User Manual

Page 24

Advertising
background image

Communication manual 8400 motec EtherCAT®

Installation

Electrical installation

24

L

EDS84DMOTECAT EN 2.1 - 11/2012

5.2.3

External voltage supply

 The external voltage supply can be used to establish EtherCAT communication for

commissioning purposes and to query the data of the digital and analog inputs.

 Moreover, the external voltage supply serves to keep up EtherCAT communication in

the event of a main supply failure.

 The digital inputs RFR, DI1 ... DI5 and the analog inputs can be evaluated as before.
 The external voltage supply is done via the terminals 24E and GND of the terminal strip

X3.

 Permissible voltage (DC) / max. current:

– U = 24 V DC (20 V - 0 % ... 29 V + 0 %)
– I

max

= 400 mA

 Access to parameters of a device that is disconnected from the mains is not possible.

"Inverter Drives 8400 motec" hardware manual
Here you can find detailed information on how to wire the Communication Unit.