Parameter data transfer

Reading and writing parameters

44

L

EDS84DMOTECAT EN 2.1 - 11/2012

9.2

Reading and writing parameters

Parameters ...

 are set e.g. for one-time system settings or if materials are changed within a machine.
 are transmitted with a low priority.

In the case of Lenze controllers, the parameters to be changed are contained in codes.

Indexing of the Lenze codes
The codes of the Inverter Drive 8400 motec are addressed by the index when accessed via

the Communication Unit.
The index of Lenze code numbers within the manufacturer-specific area of the object

directory is between 8192 (0x2000) and 24575 (0x5FFF).

Structure of a mailbox datagram
Mailbox data are transmitted in a datagramm within an EtherCAT frame. The data area of

the mailbox datagram has the following structure:

Conversion formula
Index [dec]

Index [hex]

24575 - Lenze code

0x5FFF

- Lenze code

hex

Example of C00002 (device commands)
Index [dec]

Index [hex]

24575 - 2 = 24573

0x5FFF - 2 = 0x5FFD

Mailbox

Header

CoE

Header

SDO control

byte

Index

Subindex

Data

Data

6 bytes

2 bytes

1 byte

2 bytes

1 byte

4 bytes

1 ... n bytes