3 implemented coe objects, Implemented coe objects, Communication manual 8400 motec ethercat – Lenze E84DGFCT User Manual

Page 53: Parameter data transfer implemented coe objects

Advertising
background image

EDS84DMOTECAT EN 2.1 - 11/2012

L

53

Communication manual 8400 motec EtherCAT®

Parameter data transfer

Implemented CoE objects

9.3

Implemented CoE objects

Lenze devices can be parameterised with both Lenze codes and the manufacturer-

independent "CoE objects". In order to comply fully with EtherCAT communication, you

may only use the CoE objects for parameterisation. The CoE objects described in this

manual are defined in the "EtherCAT Specification, Part 6 – Application Layer Protocol

Specification".

R: Read access only

RW: Read and write access

Index

Designation

Subindex Subindex name

Type

Bits

Access

0x1000

Device type

-

-

UDINT

32

R

0x1001

Error register

-

-

USINT

8

R

0x1008

Device name

-

-

STRING(8)

64

R

0x1009

Hardware version

-

-

STRING(8)

64

R

0x100A

Software version

-

-

STRING(7)

56

R

0x1018

Identity

0

Number of elements

USINT

8

R

1

Vendor ID

UDINT

32

R

2

Product code

UDINT

32

R

3

Revision number

UDINT

32

R

4

Serial number

UDINT

32

R

0x1600

RxPDO 1

0

Number of elements

USINT

8

RW

1 … 8

Output object 1 … 8

UDINT

32

RW

0x1A00

TxPDO 1

0

Number of elements

USINT

8

RW

1 … 10

Input object 1 … 10

UDINT

32

RW

0x1C00

Sync Man Communication type

0

Number of elements

USINT

8

R

1

Elements

UDINT

32

R

0x1C10

Sync Man 0 Assignment

0

-

UINT

16

R

0x1C11

Sync Man 1 Assignment

0

-

UINT

16

R

0x1C12

Sync Man 2 Assignment

0

Number of assigned RxPDOs

USINT

8

R

1

PDO Mapping object index of

assigned RxPDO

UDINT

32

R

0x1C13

Sync Man 3 Assignment

0

Number of assigned TxPDOs

USINT

8

R

1

PDO Mapping object index of

assigned TxPDO

UDINT

32

R

0x1C32

Sync Man 2 Synchronization

0

Number of elements

USINT

8

R

1

Synchronization type

UINT

16

R

2

Cycle time / ns

UDINT

32

R

3

Shift time / ns

UDINT

32

R

4

Sync types supported

UINT

16

R

5

Minimum cycle time / ns

UDINT

32

R

6

Minimum shift time / ns

UDINT

32

R

0x1C33

Sync Man 3 Synchronization

0

Number of elements

USINT

8

R

1

Synchronization type

UINT

16

R

2

Cycle time / ns

UDINT

32

R

3

Shift time / ns

UDINT

32

R

4

Sync types supported

UINT

16

R

5

Minimum cycle time / ns

UDINT

32

R

6

Minimum shift time / ns

UDINT

32

R