2 parameters relevant for ethercat communication, C13850 | all words from drive to master, C13851 | all words from master to drive – Lenze E84DGFCT User Manual

Page 67: C13859 | all words to standard device, Parameters relevant for ethercat communication, C13850, C13851, C13859, Communication manual 8400 motec ethercat

Advertising
background image

EDS84DMOTECAT EN 2.1 - 11/2012

L

67

Communication manual 8400 motec EtherCAT®

Parameter reference

Parameters relevant for EtherCAT communication

13.2

Parameters relevant for EtherCAT communication

This chapter lists the EtherCAT parameters of the Communication Unit in numerically

ascending order.

C13850

C13851

C13859

Parameter | Name:

C13850 | All words from drive to master

Data type: UNSIGNED_16

Index: 10725

d

= 29E5

h

Display of the process data words (subcodes 1 ... 10) which are transferred from the controller to the master.

Only those which are configured are valid.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13850/1

1st word

...

...

C13850/8

8th word

C13850/9

I/O data 1

C13850/10

I/O data 2

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13851 | All words from master to drive

Data type: UNSIGNED_16

Index: 10724

d

= 29E4

h

Display of the process data words (subcodes 1 ... 8) which are transferred from the master to the controller.

Only those which are configured are valid.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13851/1

1st word

...

...

C13851/8

8th word

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13859 | All words to standard device

Data type: UNSIGNED_16

Index: 10716

d

= 29DC

h

Number of process data words to be sent
Display area

(min. value | unit | max. value)

0

10

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT