13 parameter reference, C01501 | resp. to communication error with mci, C01503 | mci timeout – Lenze E84DGFCT User Manual

Page 66: Parameter reference, In code, C01501, C01501/2, Communication manual 8400 motec ethercat

Advertising
background image

Communication manual 8400 motec EtherCAT®

Parameter reference

Communication-relevant parameters of the operating system

66

L

EDS84DMOTECAT EN 2.1 - 11/2012

13

Parameter reference

This chapter complements the parameter list and table of attributes in the software

manual and the »Engineer« online help for the Inverter Drive 8400 motec by the

parameters for the EtherCAT communication.

13.1

Communication-relevant parameters of the operating system

This chapter lists the communication-relevant parameters of the 8400 motec operating

system in numerically ascending order.

C01501

C01503

Software manual/»Engineer« online help "Inverter Drives 8400 motec"
Here you will find general information about parameters.

Parameter | Name:

C01501 | Resp. to communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring functions for the Communication Unit
Selection list

0 No response
1 Error
4 Warning locked

Subcodes

Lenze setting

Info

C01501/1

1: Error

Resp. to MCI error 1

• Response to a communication error.

C01501/2

1: Error

Resp. to MCI error 2

• Response to troubled Communication Unit.

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Scaling factor: 1

Parameter | Name:

C01503 | MCI timeout

Data type: UNSIGNED_16

Index: 23072

d

= 5A20

h

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C01503/1

200 ms

MCI timeout

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Scaling factor: 1

Advertising