Installation
Electrical installation

5

2111 INTERBUS fieldbus module

5.4

5.4.3

L

5.4-3

EDSIBS-1.0-06/2003

5.4.3

Electrical installation

)

)

)

)

Note!

An additional mains isolation is required, if

l

a 820X or 821X is connected to an INTERBUS master and

l

a safe mains isolation (double basic insulation) is required
according to VDE 0160.

Use e.g. a bus terminal or an interface module for the INTERBUS
master with an additional mains isolation (see the corresponding
information of the manufacturer).

l

The bus system must be designed as a ring.

l

Go-and-return lines are both in the same bus cable.

l

The ring connects the INTERBUS master with all devices connected to the
bus.

Wiring to the INTERBUS master