Installation
Electrical installation
5
2111 INTERBUS fieldbus module
5.4
5.4.3
L
5.4-3
EDSIBS-1.0-06/2003
5.4.3
Electrical installation
)
)
)
)
Note!
An additional mains isolation is required, if
l
a 820X or 821X is connected to an INTERBUS master and
l
a safe mains isolation (double basic insulation) is required
according to VDE 0160.
Use e.g. a bus terminal or an interface module for the INTERBUS
master with an additional mains isolation (see the corresponding
information of the manufacturer).
l
The bus system must be designed as a ring.
l
Go-and-return lines are both in the same bus cable.
l
The ring connects the INTERBUS master with all devices connected to the
bus.