2111 interbus fieldbus module – Lenze EMF2111IB User Manual

Page 41

Advertising
background image

Data transfer
Process data signals of Lenze controllers

5

2111 INTERBUS fieldbus module

5.6

5.6.2

L

5.6-19

EDSIBS-1.0-06/2003

5.6.2.4

Process data signals for 9300 servo PLC and Drive PLC

The following data can be assigned to the PE data:

Index

Subindex

Name/variable name

Explanation

Lenze setting: Index 6000

hex

6041 0

DRIVECOM status word

PI data word 1

6044 0

DRIVECOM speed

Actual speed [rpm]

PI data word 2

6054 0

DRIVECOM actual percentage
value

Actual speed [%]

5F69 0

Device status word
(AIF1_DctrlStat)

5CA5 1

AIF_nOutW1_a

AIF word 1

5CA5 2

AIF_nOutW2_a

AIF word 2

PI data word 3

5CA5 3

AIF_nOutW3_a

AIF word 3

5CA5 4

AIF2_nOutW1_a

AIF word 4

5CA5 5

AIF2_nOutW2_a

AIF word 5

5CA5 6

AIF2_nOutW3_a

AIF word 6

5CA5 7

AIF2_nOutW4_a

AIF word 7

5CA5 8

AIF3_nOutW1_a

AIF word 8

5CA5 9

AIF3_nOutW2_a

AIF word 9

5CA5 10

AIF3_nOutW3_a

AIF word 10

5CA5 11

AIF3_nOutW4_a

AIF word 11

5CA4 0

AIF1_dnOutD1_p

AIF double word 1

)

)

)

)

Note!

9300 Servo PLC

Please execute the following logic operations in the PLC program
of the controller:

AIF1_wDctrlCtrl

W DCTRL_wAIF1Ctrl

DCTRL_wStat

W AIF1_wDctrlStat

Drive PLC

It is necessary to use the device control for the Drive PLC.

Process data telegram from
drive

Show/Hide Bookmarks