2111 interbus fieldbus module, 3 technical data, 1 general data and application conditions – Lenze EMF2111IB User Manual

Page 5: 2 rated data, 3 protocol data

Advertising
background image

Technical data
General data and application conditions

5

2111 INTERBUS fieldbus module

5.3

5.3.1

L

5.3-1

EDSIBS-1.0-06/2003

5.3

Technical data

5.3.1

General data and application conditions

Field

Values

Order number

EMF 2111IB

Communication media

RS485

Network topology

Ring

INTERBUS participant

Slave

Communication profile

PCP 1.5

Drive profile

DRIVECOM profile 21

Baud rate

500 kBit/s

Baud rate

500 kBit/s

Ambient temperature

during operation:
during transport:
during storage

0

°C

-25

°C

-25

°C

to
to
to

55 °C
70 °C
60 °C

Permissible humidity

Class 3K3 to EN 50178
(without condensation, average relative humidity 85%)

Degree of pollution

VDE0110, part 2, pollution degree 2

Enclosure

IP 20

Voltage supply (internal / external),
see

^ 5.4-5

External supply via separate power supply unit
(+24 V DC ±10 %, max. 150 mA)

5.3.2

Rated data

Insulation voltage between bus and ...

Rated insulation voltage

Type of insulation

Earth reference / PE

50 V AC

Mains isolation

External supply (terminal 39/59)

0 V AC

No mains isolation

Power stage

– 820X / 821X

270 V AC

Basic insulation

– 822X / 8200 vector

270 V AC

Double insulation

– 93XX

270 V AC

Double insulation

Control terminals

– 820X / 8200 vector

(with internal supply)

0 V AC

No mains isolation

– 8200 vector

(with external supply)

100 V AC

Basic insulation

– 821X

50 V AC

Mains isolation

– 822X

270 V AC

Basic insulation

– 93XX

270 V AC

Basic insulation

5.3.3

Protocol data

Field

Values

Maximum number of participants

62

Process data words (PD)

L-C1910 = 4: 2 words (32 bit)
L-C1910 = 6: 3 words (48 bit)

à

Lenze setting

Parameter data words (PCP)

1 (16 bit)

Maximum number of data words

The maximum number of data words (PD + PCP) is 4.

INTERBUS ID (module ID)

227

dec

= E3

hex

PCP 1 word

Maximum PDU length

64 byte

Supported PCP services

Initiate, abort, status, identify, Get-0V-long, read, write

Show/Hide Bookmarks

Advertising