2111 interbus fieldbus module, Installation electrical installation, Show/hide bookmarks – Lenze EMF2111IB User Manual

Page 12

Advertising
background image

Installation

Electrical installation

5

2111 INTERBUS fieldbus module

5.4
5.4.3

L

5.4-4

EDSIBS-1.0-06/2003

£

400

m

£ 400 m

3.1

INTERBUS-Loop 100 m

£

£ 10 m

82XX

+

2112

8200 vector

+

2111

93XX

+

2111

82XX

+

2111

93XX

+

2112

8200 vector

+

2112

3.1

3.1

3.2

3.2

3.2

3.2

4.2

4.2

4.2

4.2

2

4

4.1

4.1

4.1

1

3

2111IBU001

Fig. 5.4-2

Wiring example, INTERBUS (baud rate 500 kbit/s)

Pos.

Element

Explanation

1

INTERBUS master with
interface module

The bus system is a master-slave system, i.e. an INTERBUS master is connected
to several field devices (slaves).

2

INTERBUS loop bus
terminal

The bus terminal connects a long distance bus to a peripheral bus.

3

Remote bus
Fig. 5.4-2 Pos. 3

The following connections are possible with remote buses:

•

the INTERBUS master interface module and first bus terminal or first 2111
fieldbus module.

•

the bus terminal and the 2111 fieldbus module

•

two 2111 fieldbus modules

3.1

Long distance bus module Bus participant in the long distance bus; e.g. Lenze controller with INTERBUS

module (slave). Networking does not require bus terminals.

3.2

Remote bus cable

Connects the INTERBUS master interface module with the bus terminal and/or
the long distance bus modules.

4

INTERBUS loop, peripheral
bus
Fig. 5.4-2 Pos. 4

Connection in a peripheral-bus station
A peripheral-bus station consists of:

•

a bus terminal (Fig. 5.4-2 pos. 2)

•

up to eight peripheral bus modules (Fig. 5.4-2 pos. 3)

4.1

INTERBUS loop module

Bus participant in the INTERBUS loop; e.g. Lenze controller with INTERBUS loop
module 2112

4.2

INTERBUS loop cable

Connection within the loop

Features:
Communication medium

RS485

Network topology

Ring

Maximum number of controllers

62

Baud rate / cable length

500 kbit/s / 400 m

Specification of INTERBUS remote bus cable

5

Cable type

Yard goods:
IBS RBC Meter-T, order No. 28 06 28 6 (Fa. Phoenix Contact)

Number of conductors

3 x 2, paired with common shielding

Conductor cross-section

> 0.2 mm

2

DC cable resistance

< 96

Ω/km

Impedance, characteristic

120

Ω ± 20 % (f = 64 kHz)

100

Ω ± 15 Ω (f > 1 MHz)

Capacitance per unit length

< 60 nF/km (f = 800 Hz)

Wiring example