Data transfer
DRIVECOM profile parameters

5

2111 INTERBUS fieldbus module

5.6

5.6.7

L

5.6-43

EDSIBS-1.0-06/2003

5.6.7.7

Ramps

The DRIVECOM profile 21 provides two ramps for the speed setpoint:

l

The absolute ramp is determined by the following ramp gradient:

dк~ЗбЙен =

aÉäí~|лйЙЙЗ

aÉäí~|нбгЙ

The absolute ramps in the DRIVECOM profile 21 are ” acceleration” ,
” deceleration” and ” quick stop” .

l

The relative ramp is determined by the following ramp gradient:

dк~ЗбЙен =

péÉÉÇ кЙСЙкЙеЕЙ о~дмЙ

aÉäí~|нбгЙ

This definition corresponds to the Lenze ramp functions L-C0012 and L-C0013.
The relative ramps in the DRIVECOM profile 21 are ” acceleration time” ,
” deceleration time” and ” quick-stop time” .

The ” ramp-min function” determines and activates the slower ramp. The absolute
ramps are deactivated in Lenze setting.

This parameter contains data of the absolute speed ramp for acceleration.

Ramp gradient:

Gradient =

Delta_speed

Delta_time

The parameter is mapped to the Lenze acceleration ramp (L-C0012) via the
” ramp-min-function” .

” Delta_time“ = 0: Ramp is switched off.

Parameter name (Index)

Subindex

Data structure

Data type

Value range

Speed acceleration (6048

hex

)

1

RS (21

hex

)

U32

0 to 4294967295
0: Delta_speed [rev/min]

2

RS (21

hex

)

U16

0 to 65535
0 (ramp is switched off):

Delta_time [sec]

The ” ramp-min function” determines and activates the slower ramp. The absolute
ramps are deactivated in Lenze setting.

Speed ramps fro acceleration