Data transfer
Process data signals of Lenze controllers

5

2111 INTERBUS fieldbus module

5.6

5.6.2

L

5.6-13

EDSIBS-1.0-06/2003

Control word AIF-CTRL for 8200 vector (Lenze code C0135, index 5F78

hex

)

AIF-CTRL.Bxx

Default setting:

C0001=3 if C0007 51

Default setting:

C0001=3 if C0007 > 51

Adjustable in L-C0410/..

00,

00 = C0046 active
01 = NSET1-JOG1 (C0037) active

1

00,
01

01

NSET1 JOG1 (C0037) active

10 = NSET1-JOG2 (C0038) active
11 = NSET1-JOG3 (C0039) active

Freely configurable by user

1
2

02

DCTRL1-CW/CCW

0 = not active
1 = active

3

03

AIF-CTRL-QSP

0 = not active
1 = active

AIF-CTRL-QSP

0 = not active
1 = active

4

04

NSET1-RFG1-STOP

0 = not active
1 = active

5

05

NSET1-RFG1-0

0 = not active
1 = active

6

06

MPOT1-UP

0 = not active
1 = active

Freely configurable by user

7

07

MPOT1-DOWN

0 = not active
1 = active

8

08

Freely configurable by user

9

09

AIF-CTRL-CINH

0 = not active
1 = active

AIF-CTRL-CINH

0 = not active
1 = active

10

10

AIF-CTRL-TRIP-SET

0 = not active
1 = active

AIF-CTRL-TRIP-SET

0 = not active
1 = active

11

11

AIF-CTRL-TRIP-RESET

0 -> 1 = Edge from 0 to 1 AIF-CTRL-TRIP-RESET

0 -> 1 = Edge from 0 to 1 12

12

DCTRL1-PAR2/4

0 = not active
1 = active

13

13

DCTRL1-PAR3/4

0 = not active
1 = active

Freely configurable by user

14

14

MCTRL1-DCB

0 = not active
1 = active

15

15

Freely configurable by user

Freely configurable by user

16

AIF

AIF-IN

AIF-CTRL

AIF-IN.W2

AIF-IN.W1

.B15

.B12

.B0

.B1

.B2

.B3

.B4

...

...

...

...

...

...

...

...

...

...

...

...

.B8

.B9

.B10

.B11

DCTRL

QSP

CINH

TRIP-SET

TRIP-RESET

DCTRL

16 bits

16 bits

16 bits

2141LON011_en

Fig. 5.6-4

Function block AIF-IN in 8200 vector (freely programmable assignment)