Troubleshooting

DRIVECOM error codes

5

2111 INTERBUS fieldbus module

5.7
5.7.4

L

5.7-6

EDSIBS-1.0-06/2003

Lenze error

abbreviation

Meaning

DRIVECOM error code [hex]

Lenze error no.

CE0

61

8100

AIF time monitoring

CE1.4
CE11-14

62-65
122-125

8100

CAN time monitoring

CE5

66

8100

CAN time OUT

P16

166

8100

Sync telegram transmission error

240

8100

Free CAN obj. send memory overflow

241

8100

Free CAN obj. too many telegrams
received

P18

168

8200

Internal limitation

NMAX

200

8400

Nmax system speed

P04

154

8500

Negative position error

P05

155

8500

Positive position error

P06

156

8500

Home position not known

P07

157

8500

Absolute program set mode

P08

158

8500

Act. home position exceeding position
limits

P12

162

8500

Encoder area error

P13

163

8500

Angle overrun

P03,14,15

153/164-165

8611

Contouring error

P21

171

8611

RC contouring error

P01

151

8612

Limit-stop switch negative

P02

152

8612

Limit-stop switch positive

EEr

91

9000

External trip

)

)

)

)

Note!

Only faults and errors caused by the controller can occur.
Please read the Operating Instructions for the controller.

Show/Hide Bookmarks