2111 interbus fieldbus module, Data transfer drivecom control – Lenze EMF2111IB User Manual

Page 53

Advertising
background image

Data transfer
DRIVECOM control

5

2111 INTERBUS fieldbus module

5.6

5.6.6

L

5.6-31

EDSIBS-1.0-06/2003

Command

Meaning

COMMAND 2, 6, 8 (standstill)
Control word: bit 0 = 0

Command to change from different states to the status ”READY TO SWITCH
ON“.

COMMAND 3 (switch on)

Command to change to the controller status ”SWITCHED ON“.

COMMAND 4 (enable operation)

Command to change to the controller status ”OPERATION ENABLED“.
The controller inhibit is deactivated.

COMMAND 5 (inhibit operation)

Command to change to the controller status ”SWITCHED ON“.
The controller inhibit is activated.

COMMAND 7, 9, 10, 12 (voltage
inhibit)

Control word: bit 1 = 0

Command to change to the controller status ”SWITCH ON INHIBIT“.
The controller inhibit is activated.

COMMAND 7, 10, 11 (quick stop)
Control word: bit 2 = 0

Command to change to the controller status ”SWITCH ON INHIBIT“.
If the controller was enabled, it is decelerated in a controlled way along the

Lenze quick-stop ramp.

COMMAND 13 (malfunction/TRIP))

The controller has recognised a malfunction. For some malfunction a
controlled deceleration may be necessary (depending on the controller).

Once completed, the controller changes to the status FAULT.

COMMAND 14 (reset fault/TRIP)
Control word: bit 7 = 0 ⇒ 1

With the series 821X, 8200 vector this command acknowledges an error.
The controller changes to the status ”SWITCH ON INHIBIT“ when a fault is no

longer recognised.

)

)

)

)

Note!

The single bit-control commands depend on other bit positions.
In the following you will find a description of the bits required to
effect the command.

Controller status commands

Bits of the control word

Bit

7

6

5

4

3

2

1

0

1 Standstill

1

1

0

2 Switch on

1

1

1

3 Operation enable

1

1

1

1

4 Operation inhibit

0

1

1

1

5 Voltage inhibit

0

6 Quick stop

0

1

8 Error reset

0

®1

Error reset

RFG-zero

RFG-stop

RFG inhibit

Operation enable

Quick stop

Voltage inhibit

Switch on

0

= Bit status is 0

1

= Bit status is 1

no entry

= Any bit status, no influence

Explanation of the commands in
the status diagram for
DRIVECOM control

Show/Hide Bookmarks

Advertising