Data transfer
Process data preconfiguration depending on L-C0009

5

2111 INTERBUS fieldbus module

5.6

5.6.3

L

5.6-23

EDSIBS-1.0-06/2003

5.6.3

Process data preconfiguration depending on L-C0009

Use L-C0009 to assign predefined values to the process data words (see table
below).

This preconfiguration is meant to help you with applications which do not require
a PCP.

Presettings for the process data configuration can be made under code L-C0009
using the Drive PLC or any controller (82XX, 8200 vector, 93XX) even if the
INTERBUS is not connected.

It is also possible to configure the fieldbus module through the parameter channel
via index 6000

hex

and 6001

hex

.

The process data configuration resulting from L-C0009 is automatically

l

stored in the process data description structure when the device is
switched on.

WIndex 6000

hex (¶ 5.6-5)

/ Index 6001

hex (¶ 5.6-5)

.

l

immediately active.

l

automatically writes the process data length (PD) in L-C1910 and
DRIVECOM in L-C1911 from the table. A change of the PD length will only
become active after mains switching.

The default setting of L-C0009 is “ 1” and influences the process data
configuration.

L-C0009

PD length (L-C1910)

DRIVECOM (L-C1911)

PD word 1

PD word 2

PD word 3

11

2

0

GSTW

AIF-W1

-

12

2

0

AIF-W1

AIF-W2

-

13

2

0

AIF-W2

AIF-W3

-

14

2

1

DCSTW*

DCG

-

15

2

1

DCSTW*

DCG %

-

16

2

1

DCSTW*

AIF-W1

-

17

2

0

GSTW

DCG

-

18

2

0

GSTW

DCG %

-

21

3

1

DCSTW*

DCG

AIF-W2

22

3

1

DCSTW*

DCG %

AIF-W2

23

3

1

DCSTW*

AIF-W1

AIF-W2

24

3

1

DCSTW*

AIF-W2

AIF-W3

25

3

0

GSTW

AIF-W1

AIF-W2

26

3

0

GSTW

AIF-W2

AIF-W3

27

3

0

AIF-W1

AIF-W2

AIF-W3

*

GSTW:
AIF-Wx:
DCSTW:
DCG
DCG %:

^ 5.6-29

Device control word/device status word
AIF-IN/OUT.Wx
DRIVECOM control word/DRIVECOM status word
DRIVECOM speed [rpm]
DRIVECOM speed [%]