Data transfer
Configuration of the parameter data channel (PCP communication)

7

Feldbus-Baugruppe 2113 INTERBUS

7.6

7.6.8

L

7.6-51

EDSIBS-1.0-06/2003

The PCP service ” Get-OV“ reads the object description for each parameter and
data type.

The PCP service ” Identify“ informs about the controller identification. The
controller returns the following parameters:

Name

Value

Meaning

Name of the manufacturer

”Lenze“ (as visible string)

Company name

Controller name

Visible string with 15
characters

Unit name for controller and bus-interface module

Controller version

Visible string with 15
characters

Software version of the controller

Controller name

The visible string consists of the following characters:

l

Characters 1 to 5: Name of the controller
(4 characters for the controller name plus 1 blank)

l

Characters 6 to 10: Name of the fieldbus module
(4 characters for the controller name plus 1 blank)

l

Characters 11 to 15: No name
(5 blanks)

If a fieldbus module is not available, the corresponding area will be filled with
blanks.

Example:

8200 vector controller with 2113 fieldbus module: ” 8212 2113“

sáëáÄäÉ лнкбеЦ

`зенкзддЙк е~гЙ
_~лбЕ мебн

`зенкзддЙк е~гЙ
cáÉäÇÄìë гзЗмдЙ

_д~ев

8

2

1

2

2

1

1

3

N

S

NN

NR

Controller version

The visible string consists of the following characters:

l

Characters 1 to 5: software version of the controller:

– 2 characters for the basic version

– 2 characters for the variant

– 1 character for the version of the variant

l

Characters 6 to 10: software version of the fieldbus module

– 2 characters for the basic version

– 2 characters for the variant

– 1 character for the version of the variant

l

Characters 11 to 15: No name

– 5 blanks

Get-OV

44

Identify

45

Show/Hide Bookmarks

Advertising