Appendix

Code table

7

Feldbus-Baugruppe 2113 INTERBUS

7.8
7.8.1

L

7.8-2

EDSIBS-1.0-06/2003

7.8.1.2

Controller codes

Code

Values

Lenze

setting

Explanation

L-C0001

Operating mode

0
1
2
3

Control source
Terminal
Terminal
Terminal
INTERBUS

Setpoint source
Terminal
8201BB
Terminal
INTERBUS

Parameter source
INTERBUS
INTERBUS (operating

module)
INTERBUS
INTERBUS

L-C0009

Process data preconfiguration

)

Please see the notes in chapter 7.8.2

L-C0142

This parameter L-C0142 prevents the drive from uncontrolled restarts
after:

Mains switching

Internal fault

Internal message (with pulse inhibit) > 0.5 s

If the controller sets the status ”message” because of a failure (e.g. short

mains failure) and the fault remains active for longer than 0.5 s, controller

inhibit will be set automatically.
The parameter L-C0142 has the following function:

L-C0142 = 1:

The drives will restart automatically as soon as the error has been
eliminated.

L-C0142 = 0:
The controller remains inhibited and the drive cannot restart even if

the error has been eliminated.

– The drive restarts after a LOW-HIGH transition at one of the inputs

for ”controller inhibit” (CINH, e.g. at terminal X5/28) wieder an

All codes are described in detail in the corresponding Operating Instructions.