Possible settings with INTERBUS master

7

Feldbus-Baugruppe 2113 INTERBUS

7.5
7.5.3

L

7.5-4

EDSIBS-1.0-06/2003

7.5.3

Possible settings with INTERBUS master

)

)

)

)

Note!

Conditions for setting through the INTERBUS master:

Switch S1 ... S7 = OFF

l

The configurations set for the codes L-1910, L-1911 and
L-1912 get active with switching on.

l

The settings can be changed.

l

Switch off the voltage supply of the fieldbus module and
afterwards on again, in order to activate changed settings.

As a maximum the data word sum (PD + PCP) is to amount to 10
words.

Index detection: 24575 - Lenze code number (L-C xxxx )

Impermissible settings are indicated by the yellow bus LED
(communication)

(

¶ 7.4-1)

.

Code

Values

Explanation

L-C1910

2 ... 20 (1 ... 10 words)

Number of process data bytes
(2 Process data bytes = 1 Process data word)

L-C1911

0: Device control AIF-CTRL

Operation with device control AIF-CTRL or

1: DRIVECOM control

p

operation with DRIVECOM-Profil 21

L-C1912

Number of parameter

data words (PCP)

ID code

Number of parameter data words (PCP)

0

3

hex

1

E3

hex

2

E0

hex

4

E1

hex

Code

Explanation

L-C1915

Display of the current switch positions S1 ... S4 for number of process data words

L-C1916

Display of the current position of switch S7

L-C1916

Display of the current position of switch S7.

L C1917

Displa of c rrent s itch positions S5/S6 for n mber of parameter data ords (PCP)

L-C1917

Display of current switch positions S5/S6 for number of parameter data words (PCP)

L-C1917

Display of current switch positions S5/S6 for number of parameter data words (PCP).

L-C1917

Display of current switch positions S5/S6 for number of parameter data words (PCP).

Display codes