Data transfer
DRIVECOM profile parameters

7

Feldbus-Baugruppe 2113 INTERBUS

7.6

7.6.7

L

7.6-43

EDSIBS-1.0-06/2003

The parameter indicates the pole number of asynchronous motors and is used to
convert frequency values into speed values. Only even values are possible.

Parameter name (Index)

Subindex

Data structure

Data type

Value range

Pole number (604D

hex

)

0

S

U8

2, 4, 6, ..., 254
Lenze setting:

4

This parameter is the reference value for the relative speed parameters, e.g.
nominal percentage, actual percentage and acceleration time. The parameter is
mapped to the Lenze parameter L-C0011. A conversion to frequency values is
possible. The parameter determines the internal maximum speed, which is also
active with terminal control.

Parameter name (Index)

Subindex

Data structure

Data type

Meaning

Speed reference value (604E

hex

)

0

S

U32

L-C0011

2

in [rev∕min]

This parameter is the nominal speed in percent. It is scaled to the ” speed
reference value“ (= 100 % ). When changing this parameter, also the ” nominal
speed“ will be changed. If the ” nominal speed“ exceeds the limit value of the
” nominal percentage“ of 200 % during reading, it will be returned as a value
limited to 200 % .

Parameter name (Index)

Subindex

Data structure

Data type

Value range

Percentage setpoint (6052

hex

)

0

S

I16

−32768 to 32767

(100 % = 16383)

This parameter is the ” speed reference variable“ in percent. It is scaled to the
” speed reference value“ (= 100 % ). The ” percentage reference variable“ is
multiplied by the inverse ” setpoint factor“ .

Parameter name (Index)

Subindex

Data structure

Data type

Value range

Percentage reference variable
(6053

hex

)

0

S

I16

−32768 to 32767

(100 % = 16383)

This parameter is the ” actual speed“ in percent. It is scaled to the ” speed
reference value“ .

Parameter name (Index)

Subindex

Data structure

Data type

Value range

Actual percentage (6054

hex

)

0

S

I16

−32768 to 32767

(100 % = 16383)
Map of L-C0381

Pole number (604D

hex

)

38

Speed reference value (604E

hex

)

Percentage setpoint (6052

hex

)

39

Percentage reference variable
(6053

hex

)

Actual percentage (6054

hex

)

40

Show/Hide Bookmarks