Data transfer
Process data channel configuration

7

Feldbus-Baugruppe 2113 INTERBUS

7.6

7.6.1

L

7.6-3

EDSIBS-1.0-06/2003

7.6.1.2

Setpoint source selection

The setpoint source selection for these controllers is determined under code
L-C0001 (5FFE

hex

). An evaluation of process data is only possible if code L-C0001

is set to ” 3” when the controller is operated together with the fieldbus module. The
process data channel which describes the frequency setpoint (L-C0046) and the
control word (parameter channel, L-C0135) is the setpoint source.

)

)

)

)

Note!

Please ensure that the setpoint source (L-C0001) is the same for
all parameter sets used.

The setpoint source selection for these controllers is determined under code
L-C0001 (5FFE

hex

). An evaluation of process data is only possible if code L-C0001

is set to ” 3” when the controller is operated together with the fieldbus module. The
process data channel which describes the frequency setpoint (L-C0046) and the
control word (parameter channel, L-C0135) is the setpoint source.

Check in L-C0412/x whether the assignment of setpoint source and analog signal
is correct and change, if necessary.

)

)

)

)

Note!

Please ensure that the setpoint source selection (L-C0001) is the
same for all parameter sets used.

The value in code C0005 must be set to ” xxx3” for bus operation (x = selected
preconfiguration).

Communication requires that AIF-IN 1 ... 3 or AIF-OUT 1 ... 3 and if available the
AIF management are part of the control configuration of the IEC61131 project.

82XX controllers

Controller 8200 vector

93XX controllers

Servo PLC 9300 / Drive PLC