2 rated data, Rated data, Feldbus-baugruppe 2113 interbus – Lenze EMF2113IB User Manual

Page 31: Technical data rated data

Advertising
background image

Technical data

Rated data

7

Feldbus-Baugruppe 2113 INTERBUS

7.3
7.3.2

L

7.3-2

EDSIBS-1.0-06/2003

7.3.2

Rated data

Insulation voltages between

incoming bus

and ...

Rated insulation voltage

Type of insulation

Reference earth / PE

50 V AC

Mains isolation

External supply (terminal 39/59)

50 V AC

Mains isolation

Power stage

– 820X / 821X

270 V AC

Basic insulation

– 822X / 8200 vector

270 V AC

Double insulation

– 93XX

270 V AC

Double insulation

Control terminals

– 820X / 8200 vector

(with internal supply)

0 V AC

No mains isolation

– 8200 vector

(with external supply)

100 V AC

Basic insulation

– 821X

50 V AC

Mains isolation

– 822X

270 V AC

Basic insulation

– 93XX

270 V AC

Basic insulation

Outgoing bus (OUT)

50 V AC

Mains isolation

Insulation voltages between

outgoing bus and

...

Rated insulation voltage

Type of insulation

Earth reference / PE

50 V AC

Mains isolation

External supply (terminal 39/59)

0 V AC

No mains isolation

Power stage

– 820X / 821X

270 V AC

Basic insulation

– 822X / 8200 vector

270 V AC

Double insulation

– 93XX

270 V AC

Double insulation

Control terminals

– 820X / 8200 vector

(with internal supply)

0 V AC

No mains isolation

– 8200 vector

(with external supply)

100 V AC

Basic insulation

– 821X

50 V AC

Mains isolation

– 822X

270 V AC

Basic insulation

– 93XX

270 V AC

Basic insulation

Input bus (IN)

50 V AC

Mains isolation

Show/Hide Bookmarks