Data transfer
Process data signals of Lenze controllers

7

Feldbus-Baugruppe 2113 INTERBUS

7.6

7.6.2

L

7.6-13

EDSIBS-1.0-06/2003

The following parameters can be assigned to the PO-data:

Index

Subindex

Name

Explanation

Lenze setting:

Index 60001

hex

see

6040

0

DRIVECOM control word

PO data word 1

^ 7.6-36

6042

0

DRIVECOM speed
setpoint

Speed setpoint [rpm]

PO data word 2

^ 7.6-42

6052

0

DRIVECOM percentage
setpoint

Speed setpoint [%]
100% = 16383

^ 7.6-43

5F78

0

Device control word
(L-C0135)

Table below

5CA7

1

AIF-IN.W1

AIF word 1
Frequency and speed
are normalised with
24000 ≡ 480 Hz.

5CA7

2

AIF-IN.W2

AIF word 2
Frequency and speed
are normalised with
24000 ≡ 480 Hz.

PO data word 3

AIF-IN.Wx is parameterised under code L-C0412.

)

)

)

)

Note!

The assignment of the AIF-CTRL control word to PO data is only
useful, if the Drivecom status machine is switched off. This is
achieved by entering 0 under L-C1911 or using the switch S7 at
the front.