Data transfer
Process data signals of Lenze controllers
7
Feldbus-Baugruppe 2113 INTERBUS
7.6
7.6.2
L
7.6-13
EDSIBS-1.0-06/2003
The following parameters can be assigned to the PO-data:
Index
Subindex
Name
Explanation
Lenze setting:
Index 60001
hex
see
6040
0
DRIVECOM control word
PO data word 1
^ 7.6-36
6042
0
DRIVECOM speed
setpoint
Speed setpoint [rpm]
PO data word 2
^ 7.6-42
6052
0
DRIVECOM percentage
setpoint
Speed setpoint [%]
100% = 16383
^ 7.6-43
5F78
0
Device control word
(L-C0135)
Table below
5CA7
1
AIF-IN.W1
AIF word 1
Frequency and speed
are normalised with
24000 ≡ 480 Hz.
5CA7
2
AIF-IN.W2
AIF word 2
Frequency and speed
are normalised with
24000 ≡ 480 Hz.
PO data word 3
AIF-IN.Wx is parameterised under code L-C0412.
)
)
)
)
Note!
The assignment of the AIF-CTRL control word to PO data is only
useful, if the Drivecom status machine is switched off. This is
achieved by entering 0 under L-C1911 or using the switch S7 at
the front.
Process data telegram to drive