3 technical data, 1 general data and operating conditions, 2 protective insulation – Lenze EMF2179IB User Manual

Page 30: Technical data, General data and operating conditions, Protective insulation, Emf2179ib communication module (devicenet)

Advertising
background image

EMF2179IB communication module (DeviceNet)

Technical data

General data and operating conditions

5

5.3

5.3.1

5.3-1

EDSDEN EN 02/2006

5.3

Technical data

5.3.1

General data and operating conditions

Communication-relevant data Values
Communication media

DIN ISO 11898

Network topology

Line terminated at both ends (R = 120 Ohm)

Number of nodes

Max. 63

Cable length

Max. 500 m (depending on the baud rate)

Communication profile

DeviceNet

General electric data

Values

Voltage supply

(internal / external)

See  5.4-11

Operating conditions

Values

Deviations from standard

Climatic conditions

Storage 1 K3 to IEC/EN 60721-3-1

-25 °C ... + 60 °C

Transport 2 K3 to IEC/EN 60721-3-2

Operation 3 K3 to IEC/EN 60721-3-3

0 °C ... + 55 °C

Enclosure

IP20

Degree of pollution

2 to IEC/EN 61800-5-1

5.3.2

Protective insulation

Insulation between bus and ...

Type of insulation (to EN 61800-5-1)

z

Remote earth / PE

Functional insulation

z

External supply

No insulation

z

Power stage
– 820X / 821X

Basic insulation

– 822X / 8200 vector

Reinforced insulation

– 93XX / 9300 servo PLC

Reinforced insulation

– ECS (axis module)

Reinforced insulation

z

Control terminals
– 820X / 821X / 8200 vector

Functional insulation

– 822X

Basic insulation

– 93XX / 9300 servo PLC

Basic insulation

– ECS (axis module)

Basic insulation

Advertising