Emf2179ib communication module (devicenet) – Lenze EMF2179IB User Manual

Page 73

Advertising
background image

EMF2179IB communication module (DeviceNet)

Lenze codes and DeviceNet objects

Implemented DeviceNet objects

5

5.7

5.7.2

5.7-14

EDSDEN EN 02/2006

Instance 0:

Attribute

Service(s)

Description

Data type

Value

1

GET

Revision

UINT

0001

hex

Instance 1:

Attribute

Service(s)

Description

Data type

Value

1

GET/SET

I/O data

length in

words

UINT

1 – 12 (0000

hex

– 000C

hex

),

Default: 2, (saved in EEPROM)

Services:

Service code

Name

Description

0E

hex

Get_Attribute_Single

Reading of an attribute

10

hex

Set_Attribute_Single

Writing of an attribute

Note!

ƒ

If the I/O data length is changed, the DeviceNet scanner will

be informed about this change (produced/consumed data

size).

ƒ

If the I/O data length is reduced, it must be checked before, if

the intended data length is sufficient for the application.

ƒ

The parameters of 66

hex

are described in the EDS file and

therefore can be directly set in the feature dialog of the

DeviceNet nodes under ”Parameters” via the »RSNetWorx«

Rockwell software.

ƒ

In case of a number of process data words deviating from the

Lenze setting (2 words), the ”Automap on Add” function in the

scanner configuration dialog of the »RSNetWorx« software

has to be deactivated, and the number of process data words

has to be adjusted via the ”Edit I/O parameters” button.

Manufacturer-specific class

102 (66

hex

)

Advertising