EMF2179IB communication module (DeviceNet)
Commissioning
Preparing the basic device for communication
5
5.5
5.5.4
5.5-10
EDSDEN EN 02/2006
Note!
In some cases the controller should not restart after a fault (e.g.
after a short mains failure).
ƒ
The drive can be inhibited by setting C0142 = 0 if
–
the corresponding controller sets a fault ”LU message” and
–
the fault is active for more than 0.5 seconds.
Parameter function:
ƒ
C0142 = 0
–
The controller remains inhibited even after the fault has
been eliminated and
–
the drive restarts in a controlled mode: LOW-HIGH transition
at terminal 28 (CINH)
ƒ
C0142 = 1
–
An uncontrolled restart of the controller is possible.
Lenze codes in the basic device and communication module can
be read and written via the vendor-specific class 110. An
example is included in the appendix of the DeviceNet Manual
(Class Instance Editor).
Protection against
uncontrolled restart