EMF2179IB communication module (DeviceNet)
Lenze codes and DeviceNet objects
Implemented DeviceNet objects
5
5.7
5.7.2
5.7-17
EDSDEN EN 02/2006
5.7.2.1
Examples for reading / writing with the »Class Instance Editor«
Tip!
The »Class Instance Editor« is a function of the
»RSNetworx«Rockwell software
Example 1: writing to the code
The maximum speed (n
max
) is to be set to 3000 min
-1
via code C0011 .
Please enter the following in the »Class Instance Editor« (see graphics):
ƒ ”Description”: set single attribute (write to code).
ƒ ”Class”: 6E (access to Lenze code)
ƒ ”Instance”: B (hex value of the code)
ƒ ”Attribute”: 1 (hex value of the subcode)
ƒ ”Data sent to the device”
3000 [min
-1
] ==> x 10 000 (only in this example) =
30000000
dez
= 1C9C380
hex
(enter speed as hex value)
ƒ Further information on the data format