EMF2179IB communication module (DeviceNet)

Lenze codes and DeviceNet objects

Implemented DeviceNet objects

5

5.7

5.7.2

5.7-17

EDSDEN EN 02/2006

5.7.2.1

Examples for reading / writing with the »Class Instance Editor«

Tip!

The »Class Instance Editor« is a function of the

»RSNetworx«Rockwell software

Example 1: writing to the code
The maximum speed (n

max

) is to be set to 3000 min

-1

via code C0011 .

Please enter the following in the »Class Instance Editor« (see graphics):
ƒ ”Description”: set single attribute (write to code).
ƒ ”Class”: 6E (access to Lenze code)
ƒ ”Instance”: B (hex value of the code)
ƒ ”Attribute”: 1 (hex value of the subcode)
ƒ ”Data sent to the device”

3000 [min

-1

] ==> x 10 000 (only in this example) =

30000000

dez

= 1C9C380

hex

(enter speed as hex value)

ƒ Further information on the data format

2179DEN011