Emf2179ib communication module (devicenet), Instance 2 (polled i/o data) – Lenze EMF2179IB User Manual
Page 69
EMF2179IB communication module (DeviceNet)
Lenze codes and DeviceNet objects
Implemented DeviceNet objects
5
5.7
5.7.2
5.7-10
EDSDEN EN 02/2006
Instance 2 (polled I/O data):
Attribute Service(s) Description
Data type Value
1
GET
state
USINT
Status of the object
2
GET
instance_type
USINT
1
3
GET
transportClass_trigger
BYTE
128/130 (80
hex
/82
hex
)
4
GET
produced_connection_id
UINT
Send CAN identifier
5
GET
consumed_connection_id
UINT
Reception of CAN
identifier
6
GET
initial_comm_characteristics
BYTE
1 (01
hex
)
7
GET
produced_connection_size
UINT
Dependent on the
number of I/O data
words
8
GET
consumed_connection_size
UINT
Dependent on the
number of I/O data
words
9
GET / SET expected_packet_rate
UINT
Connection-dependent
10/11
Not used
No longer defined
12
GET
watchdog_time-out_action
USINT
Defines time-outs
13
GET
produced_connection_path_length UINT
4
14
GET
produced_connection_path
EPATH
[20
hex
, 67
hex
, 24
hex
,
01]
15
GET
consumed_connection_path_length UINT
4
16
GET
consumed_connection_path
EPATH
[20
hex
, 68
hex
, 24
hex
,
01
hex
]
17
GET
production_inhibit_time
UINT
0