EMF2179IB communication module (DeviceNet)

Data transfer

5

5.6

5.6-2

EDSDEN EN 02/2006

Depending on their time-critical behaviour, the telegram types are divided

into corresponding communication channels.
ƒ The process data channel transmits ”I/O data”

– By means of the I/O data you can control the controller.
– The host can directly access the I/O data. The data is directly stored

int the I/O area of the PLC.

– I/O data is not stored in the controller; they are cyclically transferred

between the host and the controllers (continuous exchange of input

and output data).

ƒ The parameter data channel transmits ”explicit messages”

– Enables access to all Lenze codes.
– Saving parameter changes:

Automatic storage for the 82XX and 8200 vector frequency inverters

Manually required storage for the 93XX servo inverters

(Lenze code C0003).

Note!

ƒ

As default message type, ”Polled” is set in the communication

module.

ƒ

The selection and configuration of the message types is

effected by means of software via the scanner.

Dividing the telegram types

into communication channels