Rotary switches on the side of the MSR320 Input Module are used to set the assignment
of inputs to specific output switching groups: each group has a designated Output Module
(Output Groups 1, 2 and 3).

MSR330 Output Module:


Functions:
Safety contact outputs.
Outputs:

Each module: 3 x N/C outputs plus 1 x N/O safety contact
outputs.
System maximum:
3 x 6 = 18 N/C plus 1 x 6 = 6 N/O auxiliary contacts.

A minimum of one and a maximum of six Output Modules
can be included in a single MSR300 System.

MSR330 Output Modules are available in three versions, each specific for one of three
output groups: i.e., Group 1, Group 2, Group 3, respectively. The group number must be
specified when ordering these modules.


MSR329 Muting Lamp Module:


Functions:
Connection and control of muting lamps.
Capacity:

2 x main muting lamps plus 2 x reserve muting lamps

One Muting Lamp Module can be optionally included in an
MSR300 System in lieu of one MSR320 Input.