4.3.2 LED Indicators

Function / Diagnostics

Ch 1

Ch 2

Relay 1 on

Green

-

Relay 1 off

Off

-

Relay 2 on

-

Green

Relay 2 off

-

Off


4.4 MSR329 Muting Lamp Module





























Functions:

Connection and control of muting lamps.

Capacity:

Two main muting lamps plus two reserve muting lamps


Muting is the safe, automatic and temporary suspension of an electrosensitive protective
device, in accordance with EN 61496-1 A.7. Muting is typically applied to allow material in
process to be moved into and out of a hazardous area. Typically, muting causes the
signal inputs from safety barriers such as opto-switches or light curtains to be temporarily

MSR329 Connections

MSR329