Robot cell 3 areas, Msr300 system configuration, 0 degrees – Rockwell Automation 440R MSR300 Modular Safety Control System User Manual

Page 67: Msr300 safety system manual, Modules and i/o configuration

Advertising
background image

MSR300 Safety System Manual


Rockwell Automation

MSR300 Manual.doc

Pg 67 of 85

Robot cell 3 areas

Modules and I/O configuration

Restricted

space

Restricted

space

Muting

lamp

Muting

lamp

On

270°

90°

Operator

Load Station 1

Light curtain

muted

Operator

Load Station 2

Light curtain

active

A2

Y10

Y13

S34

Y42

Y31 Y32 Y33

Y40

Y41

Group

1 2 3

MSR310P

PW

R

Tx

D

2

S11 S21 S31

S41 S51

A1

TxD

Shield

RxD

TxD

GND

S12 S22 S32

S42 S52 S62

1 2 3

MSR320P

Input

1 2

Input 1

Input 2

Gr

13

23

14 24

MSR330P

1 2

41

33

34

44

Group 3

Channel

S12 S22 S32

S42 S52 S62

1 2 3

MSR320P

Input

1 2

Input 1

Input 2

Gr

S12 S22 S32

S42 S52 S62

1 2 3

MSR320P

Input

1 2

Input 1

Input 2

Gr

A1

A2

H21

H11

H22

H12

MSR329P

Input

1 2

Input 1

S12 S22 S32

S42 S52 S62

1 2 3

MSR320P

Input

1 2

Input 1

Input 2

Gr

Additional

safe area

0 degrees

A

B

C

E

J

F

G

H

I

D


MSR300 System configuration:

MSR310 Base Module – 1
MSR320 Input Modules – 4
MSR330 Output Module – 1
MSR329 Muting Lamp Module – 1


I/O:

A, I = Light curtain inputs
C, H = Safety mat inputs
D, F = Robot cam switch inputs
B, G = Muting lamp control
E = Robot run/stop output
J = “Addl. Safe Area” cam switch


Advertising