Low Byte:
Bit Function
7 Reserved
6

Fault: Different switch settings of input modules between the two channels

5

Fault: Invalid configuration of extension modules

4

Fault: Reserve Muting lamp 2

3

Fault: Muting lamp 2

2

Fault: Reserve Muting lamp 1

1

Fault: Muting lamp 1

0

Fault: at least one Input (lock-out-release, no synchrony activity)



Configuration status (Parameters 4 ... 13: current configuration of Extension
modules 1...10)
High Byte:
Bit Function
7

Switch settings of function bit 3

6

Switch settings of function bit 2

5

Switch settings of function bit 1

4

Switch settings of function bit 0

3

Switch settings of group bit 3

2

Switch settings of group bit 2

1

Switch settings of group bit 1

0

Switch settings of group bit 0


Low Byte:
Bit Function
7

Stored EEPROM settings of function bit 3

6

Stored EEPROM settings of function bit 2

5

Stored EEPROM settings of function bit 1

4

Stored EEPROM settings of function bit 0

3

Stored EEPROM settings of group bit 3

2

Stored EEPROM settings of group bit 2

1

Stored EEPROM settings of group bit 1

0

Stored EEPROM settings of group bit 0



Configuration status (Parameter 14: input with error monitoring)

High Byte:
Bit Function
7

Input error monitoring, extension module 8, input 2

6

Input error monitoring, extension module 8, input 1

5

Input error monitoring, extension module 7, input 2

4

Input error monitoring, extension module 7, input 1

3

Input error monitoring, extension module 6, input 2

2

Input error monitoring, extension module 6, input 1

1

Input error monitoring, extension module 5, input 2

0

Input error monitoring, extension module 5, input 1