4.2.3.9
Safety Gate and Light Curtain
Switch setting: 9
Without simultaneity monitoring of Input 1 and Input 2.
Input 1
Input 2
Solid-state auxiliary
output: Input 1
Solid-state auxiliary
output: Input 2
S11-S12: N/C
S11-S22: N/O
OSSD1-S42
OSSD2-S52
S32
S62
With simultaneity monitoring (3 second limit) of Input 1 and without simultaneity
monitoring of Input 2.
Input 1
Input 2
Solid-state auxiliary
output: Input 1
Solid-state auxiliary
output: Input 2
S21-S12: N/C
S21-S22: N/O
OSSD1-S42
OSSD2-S52
S32
S62
See respective wiring diagrams for safety door and light curtain (above).