MSR300 Safety System Manual


Rockwell Automation

MSR300 Manual.doc

Pg 64 of 85


Robot Cell, 2 areas
(Input 1 OR Group 1) AND (Input 2 OR Group 2) = Group 3 (muting with cross control)


On

Off

Restricted space

No muting

Danger zone 1

270° area

270°

Station

Danger zone 2

90° area

90°

Station

Muting

lamp 1

Muting

lamp 2



90

O

Input 1

”1”

Input 2

”0”



Input 1

Danger zone 1

270° area

Input Status

Group 1

270° station

Input 2

Danger zone 2

90° area

Input Status

Group 2

90° station

Output

Group 3

>Robot

Muting

Lamp 1

270° station

Muting

Lamp 2

90° station

1 1 0 0

0

1

0


• Base Cam switch pressed on Input 1

• Input Status on 90° station “0”: Light curtain interrupted

• Robot operation disabled (stopped) because operator enters danger zone 2 while

Robot arm is present

• No Muting Lamp indication for 90° station

• Muting Lamp on 270° station is lightning > Light curtain interruption at 90° station

would not stop Robot function