MSR300 Safety System Manual


Rockwell Automation

MSR300 Manual.doc

Pg 29 of 85


Selecting output groups:

Switch

settings

Function

LED Gr 1 LED Gr 2 LED Gr 3

0

OR logic function (*

1

)

(Group 3 = Input 1 OR Input 2 OR
Group 1)

On Off

Flashes

1

Group 1 (*²)

On

Off

Off

2

Group 2

Off

On

Off

3

Group 1 + 2

On

On

Off

4

Group 3

Off

Off

On

5

Group 1 + 3

On

Off

On

6

Group 2 + 3

Off

On

On

7

Group 1 + 2 + 3

On

On

On

8

Robot function (incl. muting)
(see chapter 5)

On On

Flashes

9

Additional Safe Area (3 zone robot
function see chapter 5)

Off Off

Flashes


(*) Explanations:

(*

1

): Switch setting 0:

This Input Module will generate a Group 3 command if at least one of the conditions
occur:
Input 1 of this Input Module is active
OR
Input 2 of this Input Module is active
OR
Group 1 output is active

(*²): Switch setting 1:
Group 1 Output Module is active if all inputs circuits to the assigned Input Module/s are
closed.

If several Input Modules are set up for logic function ("Function" switch setting = 0), then
the output of the Group 3 Output will be active only if at least one input of all these Input
Modules is active.
This OR function can be AND-logic combined with other inputs assigned to Output Group
3 (switch setting = 4,....., 7: see example below and in section 5.2).

&

Output

Group 3

>Group1

&

Input 1

>

=

Input 2

>Group3

Input 1

Input 2
Input 1

Input 2

Input 1

Input 2

Function 1

>Group 1

Function 0

>OR Logic

Function 0

>OR Logic

Function 4

>Group 3