Publication 1761-UM006E-EN-P - August 2005
Connecting CompactLogix Controllers on Ethernet 8-17
your Map PLC/SLC screen for the CompactLogix controller should
look like the following:
Figure 8.17 File Mapping for the CompactLogix Controller in RSLogix 5000
Save your program.
Download To The
CompactLogix Controller
Through Two Series A ENIs
The ladder program written for the CompactLogix controller can be
downloaded to the controller via the two ENI modules. A full-duplex
DF1 driver must be configured in RSLinx to initiate the download
through ENI #1.
1. Open RSLinx.
2. Open the configure drivers dialog box.
3. Select RS-232 DF1 devices. Click Add New.