6-6 EMail Messages (Node 50 to 99)

2. Open the message instruction and enter the appropriate

variables. The variables are described in Table 6.2.

Table 6.2 Message Instruction Variables for Sending an Email Message

Variable

Setting

This Controller Parameters:

Communication Command

485CIF/PLC2

Data Table Address

Any valid string, such as ST25:21 as shown below.

Size in Elements

1

Channel

The RS-232 communication channel that is connected to the
ENI/ENIW, typically 0 or 1.

Target Device Parameters:

Message Timeout

Increase this value to 10 or greater to avoid MSG timeouts.

Data Table Offset

Always 0.

Local Node Addr (dec).

This is the destination node address. Nodes 50 to 99 send
email messages; nodes 150 to 199 configure the email
address.

Local/Remote

Always Local.