Publication 1761-UM006E-EN-P - August 2005

1761-NET-ENIW Web Server Capabilities 7-5

Displaying Device Data

The four Data View pages show data pushed to the ENIW by the
attached device. If no data has been written to the ENIW by the
attached device or configuration utility, these pages display empty
cells. The integer and floating-point data on this page is volatile and is
cleared every time the ENIW boots.

Each of the four Data View pages are titled with either the default
“Data View Page 1 of 4" etc., or with user-defined page names. See
page 7-3 for information on how to rename the Data View pages.

Data View pages display string data in column 1 and either integer or
floating point data in column 2.

Figure 7.1 Data View Page

String Data

String Data for the Data View pages is written to Node 201, offset
elements 1 to 40 as described in Table 7.3. Strings are left-justified.

For SLC or MicroLogix 485CIF Write MSG instruction, enter the offset
value in decimal. For Logix PLC-2 Unprotected Write MSG instruction,
enter the element value in octal.