Rockwell Automation 1761-NET-ENIW MicroLogix Ethernet Interface (ENI) User Manual User Manual

Page 33

Advertising
background image

Publication 1761-UM006E-EN-P - August 2005

Operation 3-3

The subnet mask for each Ethernet device is then, 255.255.0.0.

Figure 3.1 Example Ethernet Network

131.200.50.96

computer’s Ethernet card

131.200.50.97

Series B/C/D

1761-NET-ENI/1761-NET-ENIW #3
(1769-L20 or 1769-L3x CompactLogix
controller)

131.200.50.98

Series A or B/C/D

1761-NET-ENI/1761-NET-ENIW #4
(MicroLogix 1500)

IMPORTANT

The RS-232/DF1 interface between the
CompactLogix controller and its ENI/ENIW module,
and between the computer (RSLogix5000/RSLinx)
and its ENI/ENIW module, should use 38400 baud.
This will allow the fastest upload/download of
programs.

(For series A and B ENI or series B ENIW only)
When using 38400 baud, the number of Stop Bits in
RSLinx and in the CompactLogix controller must be
set to 2.

Table 3.1 Example Network IP Addresses

IP Address

ENI or ENIW Series

Device

ETHERNET

FAULT

RS232

NET

TX/RX

TX/RX

PWR

CABLE

EXTERNAL

IP

ETHERNET

FAULT

RS232

NET

TX/RX

TX/RX

PWR

CABLE

EXTERNAL

IP

ETHERNET

FAULT

RS232

NET

TX/RX

TX/RX

PWR

CABLE

EXTERNAL

IP

ETHERNET

FAULT

RS232

NET

TX/RX

TX/RX

PWR

CABLE

EXTERNAL

IP

< > ETHERNET

...

1747-L55x (SLC 5/05)

1769-Lxx (CompactLogix)

1756-Lx (ControlLogix)

ENI #2 (Series A)

Personal Computer with

RSLogix 5000, RSLogix 500

and RSLinx

1756-ENBT

ENI #4 (Series A or B/C/D)

Ethernet

Hub/Switch

(10 Base T)

PC COMM Port

RS-232/DF1

PC Ethernet
Interface Card

RS-232/DF1

MicroLogix 1500

1769-Lxx (CompactLogix)

ENI #3
(Series B/C/D)

ENI #1 (only
necessary for
connection to
series A ENI #2)

24V dc

24V dc

24V dc