Rockwell Automation Publication 1757-UM012A-EN-P - July 2011

Appendix B Data Types and Data Structures

DS-74 - Alarm Summary Structure

This data structure consists of data that summarizes 16 alerts.

DS-85 - Test Structure

This data structure consists of function block test read/write data.

Table 22 - Alarm Summary Structure - DS-74

E

Element Name

Data Type

Size (bytes)

1

Current

Bit String

2

2

Unacknowledged

Bit String

2

3

Unreported

Bit String

2

4

Disabled

Bit String

2

Table 23 - Test Structure - DS-85

E

Element Name

Data Type

Size (bytes)

1

Value1

Boolean

1

2

Value2

Integer8

1

3

Value3

Integer16

2

4

Value4

Integer32

4

5

Value5

Unsigned8

1

6

Value6

Unsigned16

2

7

Value7

Unsigned32

4

8

Value8

FloatingPoint

4

9

Value9

VisibleString

32

10

Value10

OctetString

32

11

Value11

Date

7

12

Value12

Time of Day

6

13

Value13

Time Difference

6

14

Value14

Bitstring

2

15

Value15

Time Value

8