4-34 InView Protocol

information received. The following is an example of adding message
#0003 and removing message #0002 from the message queue.

Transmission:

Transmission for Add/Remove a Message

Response: NONE

Priority Messaging using a Modbus ASCII Query (Recommended)

This method writes to the first register in the message queue (40103).
When this happens, the previous message in the queue is replaced
with the new message to be loaded.

This is an example of sending a Priority Message #0099 to display
address 001.

Transmission:

Query for a Priority Message

Response:

The normal response to a function 06 is to echo (or re-transmit) the
query after the holding register is updated.

Beginning
of Frame

ADDR

FUNC

H.O.

ADDR

L.O.

ADDR

QUANTITY

BYTE CNT

DATA

:

FF

10

00

64

0002

04

0003 0002

LRC

Error

EOF

Ready
to rec.
resp

7E

CR

LF

Beginning
of Frame

ADDR

FUNC

H.O.

ADDR

L.O.

ADDR

DATA

LRC

Error

EOF

Ready to
rec. resp

:

01

06

00

66

0063

30

CR

LF