Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual
Page 72
Publication 2706-UM016D-EN-P - March 2006
4-6 InView Protocol
Or
Trigger a Message on a Specific Display using Priority
Messaging
The following are examples of triggering message 39 on display
address 031.
Trigger a Message on a Specific Display
Or
Name
[CTRL][T]
MSG #
Backslash
Display address
Return
ASCII
^T
45
\
255
^M
Hex
\14
\34\35
\5C
\32\35\35
\0D
Name
[CTRL][T]
MSG #
Backslash
Function
Backslash
Display
address
Return
ASCII
^T
45
\
1
\
255
^M
Hex
\14
\34\35
\5C
\31
\5C
\32\35\35
\0D
TIP
Allen-Bradley PLC processors requires two
backslashes (\\) to be used as a delimiter. Other PLC
manufactures may only require one backslash (\).
Name
[CTRL][T]
MSG #
Backslash
Display address
Return
ASCII
^T
39
\
31
^M
Hex
\14
\33\39
\5C
\33\31
\0D
Name
[CTRL][T]
MSG #
Backslash
Function
Backslash
Display address
Return
ASCII
^T
39
\
1
\
31
^M
Hex
\14
\33\39
\5C
\31
\5C
\33\31
\0D